Москва

Toshiba aquilion 64 slice ct scanner

Доставка из Европы. Год производства: 2006 MODEL Aquilion 64 X-RAY TUBE X-RAY TUBE ANODE Heat storage, hu (X-ray tube anode) 7500000 Heat dissipation rate, hu/min (X-RAY TUBE) 1, 386, 000 max Tube cooling (X-ray tube anode) Oil/air Tube focal spot, mm (X-ray tube anode) 1. 6 x 1. 4, 0. 9 x 0. 8 (IEC standard) POWER NEEDED 200 VAC, 50/60 Hz, 3-phase Type (CONFIGURATION) Multislic ehelical # of slices (X-ray tube anode) 64 TABLE FEATURES Range of movement Vertical, cm (Range of movement) 31-94. 4 Longitudinal, cm (Range of movement) 219 Scanning range, cm (Range of movement) 180 Max. patient weight, (precision), kg (Range of movement) 205 (±0. 25 mm) Image storage Hd capacity, gb (IMAGE STORAGE) 180, 720 raw data, max 3, 600 rotations No. online images (IMAGE STORAGE) 160000 Archive (IMAGE STORAGE) 9. 4 GB DVD-RAM GENERATOR Output, kw (X-RAY GENERATORS) 60 Kvp range (GENERATOR) 80, 100, 120, 135 Ma range (IMAGING SYSTEM) 1010-50 in 5 mA steps DICOM 3. 0 COMPATIBLE (POWER NEEDED, VAC) Yes PERFORMANCE Minimum interscan time, sec (PERFORMANCE) 0 Dynamic scan pace (PERFORMANCE) 200 scans/100 sec High-contrast spatial resolution 0% mtf, lp/cm (PERFORMANCE) 18 50% mtf, lp/cm (PERFORMANCE) 8 Low-contrast resolution, mm at % at =4 rads (PERFORMANCE) 2 at 0. 3% Sound, % at = 2. 5 rads (PERFORMANCE) 0. 5 DISPLAY MONITOR 18" LCD color x 2 Matrixes, pixels (DISPLAY) 1280 x 1024 Range of ct numbers (DISPLAY) -1, 536 to +8, 191 Image enlarging scale (DISPLAY) Up to 20x Max # slices displayed simultaneously (DISPLAY) 16 HELICAL SCANNING (DISPLAY) Yes Max scan time, sec (DISPLAY) 100 Max scan volume, cm (DISPLAY) 175 Spatial resolution, lp/cm (DISPLAY) 18 at 0% MTF Pitch (DISPLAY) 0. 8-96 mm/sec couch-top speed Reconstruction time per image, sec (DISPLAY) 0. 1 FLOOR SPACE NEEDED Size, m2 (FLOOR SPACE NEEDED) 27 (25 short couch) SCORING OF CORONARY ARTERY CALCIFICATION (IMAGE STORAGE) Optional IMAGE PROCESSING (MAXIMUM DISPLAY) Cpu (NETWORK/DATABASE) 32-bit processor x 2 Scan fovs, cm (IMAGE PROCESSING) 18, 24, 32, 40, 50 Image reconstruction matrixes (IMAGE PROCESSING) 512 x 512 Reconstruction time Per slice, sec (Reconstruction time) 0. 1 For localization scan, sec (Reconstruction time) Real time GANTRY Geometry (GANTRY) Rotate-rotate, slip ring, multislice DETECTOR (SCATTERED LIGHT) Solid-state Rows (GANTRY) 64 Elements/row (GANTRY) 64 x 896 # detection channels (GANTRY) 64 x 896 Rotation times, sec 360 (GANTRY) 0. 5, 0. 75, 1, 1. 5, 2, 3; optional 0. 4 Partial (GANTRY) 0. 32; optional 0. 25 Slice thickness, mm (GANTRY) 0. 5 x 64: 1 x 32; 2 x 16; 0. 5, 1, 2, 3, 4, 6, 8 (all x 4) X-ray fan beam angle, ° (GANTRY) 49. 2 Gantry angle deg (GANTRY) ±30 Gantry size, hxwxd, cm (GANTRY) 195 x 233 x 96 Gantry weight, kg (GANTRY) 1750 Gantry opening, cm (GANTRY) 72 Scan localizer (GANTRY) Laser OTHER ATTRIBUTES (Interference compensation) Cerebral blood-flow analysis syatem; quantitive bone mineral analysis; CT fluoro; full DICOM featue set; pediatric scanning; SureStart contrast tracking; SureScan real-time imaging; volume rendered 3-D; ECG gating; cardiac scoring; cardiac function analys FDA CLEARANCE (Interference compensation) Yes CE MARK (MDD) (Interference compensation) Yes MARKETING REGION (Interference compensation) Worldwide Our specifications Год производства: 2006 Serial number: HCA06Z2451 Tube model: MSC7078DREV2 Serial number: 92421-R4 (replaced 25/08/2014) Tube scan seconds: 362. 446 Gantry count: 2. 129. 181 Software version: V5. 10*R007 Including: Mallinckrodt Optivantage DH contrast injector
Город
Москва
Рубрика
Медицинские приборы

Характеристики:

Цена
6800000

Продавец: Анатолий

Дата создания: 27 мая 2018
Номер объявления: 4426942